Systron PowerShield® shieldings for electrical equipment are used as flat screen shields, room shields or component shields to limit low-frequency magnetic fields. That way, magnetic fields of transformers, busbars, cable trays, low-voltage distribution systems, USV systems, motors, generators, reactors etc. are shielded. In addition, Surface Shields are used as stray field shielding for NMR.


Systron PowerShield® transformer compact shields:

Description

Systron PowerShield® transformer compact shields
kompaktabschirmungCompact shields over two 630kVA transformers
 

With the Systron PowerShield® transformer compact shielding magnetic fields of Transformers are limited. The compact Shield was developed in cooperation with EWZ Zurich so the installation limit value, AGW, of transformers in accordance with the regulation on non-ionising radiation, NISV, can be met.
The compact shield was therefore developed for transformers with different performance and dimensions and is available in different dimensions and shielding factors for transformers up to 1600 kVA.
The shielding effect was checked by Electrosuisse. These measurements were performed with currents from 150A to 1900A.
The measurement curves show that the AGW in rooms above the transformer station, in transformer stations with the usual room heights, are respected perfectly.

Isoline 630kVA

Isoline 630kVA, 900A, 1µT - curve

iso630kva

Rot = without shielding, black = with transformer compact shielding
Source: electrosuisse Fehraltorf

Isoline 1000kVA

Isoline 1000kVA, 1460A, 1µT - curve

iso1000kva

Rot = without shielding, black = with transformer compact shielding
Source: electrosuisse Fehraltorf

Examples

Practical examples

kompaktabschirmung-1
 
kompaktabschirmung-3
 
kompaktabschirmung-4
 
kompaktabschirmung-2
 
kompaktabschirmung-5
 
kompaktabschirmung-1000kva
630kVA
 
1000kVA
 
1000kVA
 
630kVA   630kVA   1000kVA

Systron PowerShield® Surface shields:

Description

Systron PowerShield® - Surface shields

nsv-ms-raum
Surface shielding in transformer room
 

Systron PowerShield® - Surface shields are used to protect people or equipment by reducing low-frequency magnetic fields such as the ones caused by transformers, NS distribution, medium-voltage equipment and wires or electrical devices.

Systron PowerShield® - Surface shields are used to meet (legal) limits or, in terms of prevention, keep field exposure on people as small as possible.

Systron Power Shield® Surface shields are equally used for small and large areas.

The Systron Power Shield® shielding system consists of sandwich panels with a combination of magnetic and electrically conductive metals and is typically used in low-frequency magnetic fields with frequencies of 16.7Hz, 50Hz up to approximately 1000Hz. The shield panels are mounted on the floor, on walls or ceiling.

Shielding, Examplel

Proof of the effect of the surface shield system via a transformer station.

diagrammflaechen
Red: Without shielding, 20 cm height above ground 
Black: With shielding, 20 cm height above ground

 
System:
Transformer station in the basement, on the floor with a surface shield on the bottom of the above floor. On this floor office workstations (operating personnel) are being installed. The aim of these measures was to reduce the values during normal operation current as best as possible and if possible to keep them under the AGW of 1µT.
 
Red curve:
Measured values 20cm height above ground, in a distance of 1 m, measured on a line. Maximum measured value: 14.6µT
 
Black curve:
Measured values 20cm height above ground, in a distance of 1 m, measured on a line. Maximum measured value: 0.4µT
 
Result:
A reduction of >factor 30 has been achieved with the shielding*.
 
*The current was also measured during the measurements. The values in the diagram are converted to the same power and thus are comparable.
 

Examle

Practical examples

decken wand abschirmungCeiling/wall shielding in transformer station
 
magnetfeldabschirmung bodenShielded office floor above transformer station
 
bodenabschirmung serono1000 m² floor shielding above transformer station

 


Systron PowerShield® Cable tray shielding:

Description

Systron PowerShield® - Cable tray shielding
trasseeabschirmung       

Systron PowerShield® Cable tray shielding are being used for field reduction on cable trays. This type of shielding is based on the proven Systron PowerShield® composite panels. The elements are custom made.

Use: Cable trays, power rails, devices

       

Examples

Cable tray shielding

Manufacturing cable tray shielding

     Cable tray shield mounted         Cable tray shielding implementation 

trasse-produktion

 

trasse-lang

 

trasse


Go to top